EPA MAINTENANCE
REQUIREMENTS
To maintain optimum engine performance
and compliance with the Environmental
Protection Agency (EPA) Regulations for
Engines, it is essential that you follow the
Periodic Maintenance Schedule on page
54 and the Periodic Maintenance
Procedures on page 59.
EPA Requirements for USA and
Other Applicable Countries
The following are the requirements for the
EPA. Unless these requirements are met,
the exhaust gas emissions will not be within
the limits specified by the EPA.
See Conditions to Ensure Compliance with
EPA Emission Standards on page 52.
Clean or replace the air cleaner element if
the air intake restriction exceeds the
referenced specifications.
EPA Requirements
The EPA emission regulation is applicable
only in the USA and other countries that
have adapted the EPA requirements in part
or in whole. Determine and follow the
emission regulations in the country where
your engine will be operating to assist you in
specified compliance.
Conditions to Ensure
Compliance with EPA Emission
Standards
The following are the conditions that must be
met in order to ensure that the emissions
during operation meet the EPA standards.
The operating conditions should be as
follows:
Ambient temperature: -20˚ to +40˚C
(-4˚ to +104˚F)
Relative humidity: 80% or lower
Permissible value for intake negative
pressure: 204 mmAq (8 in.Aq) or lower
Permissible value for exhaust back
pressure: 1999 mmAq (78.7 in.Aq) or
lower
The diesel fuel should be:
ASTM D975 No. 1-D or No. 2-D, or
equivalent (minimum of cetane No. 45)
The lubricating oil should be:
Type API, Class CD or higher
Be sure to perform inspections as outlined
in Periodic Maintenance Procedures on
page 59 and keep a record of the results.
Pay particular attention to these important
points:
Replacing the engine oil
Replacing the engine oil filter
Replacing the fuel filter
Note: Inspections are divided into two
sections in accordance with who is
responsible for performing the inspection:
the user or the maker.
PERIODIC MAINTENANCE
52 6LPA Series Operation Manual
© 2007 Yanmar Marine International
Vista de página 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 103 104

Comentários a estes Manuais

Sem comentários