PRODUCT OVERVIEW
6LPA Series Operation Manual 21
12/05
Key (Starter) Switch
Figure 6
Figure 7
The GLOW position (Figure 7, (1)) is the
start aid position. Electric current to the air
heater (if equipped) is turned on.
The START position (Figure 7, (4)) allows
current to the starting motor. When starting
the engine, move the key to the START
position and release. The key will
automatically move to the ON position.
NEVER hold the key in the START position
for longer than 15 seconds or the starter
motor will overheat.
When the key is in the OFF position
(Figure 7, (2)) the electric current is off.
The key can be inserted or removed in this
position.
The ON position (Figure 7, (3)) allows
electrical current to the controls and
equipment and allows the engine to keep
running. To stop the engine, keep the key
switch in the ON position and push the
engine stop button. After stopping the
engine, turn key to OFF position.
Engine Stop Button
Figure 7
Figure 8
Push and hold the stop button
(Figure 8, (1)) on the instrument panel to
stop the engine. When the stop button is
pushed, the solenoid valve on the fuel
injection pumps stops the fuel supply to
the engine.
Press and hold the engine stop button until
the engine has come to a complete stop.
Releasing the engine stop button before
the engine has stopped rotating will cause
the engine to continue to run.
Remote Control (Throttle) Handle
The engine is controlled by the remote
control handle located in the cockpit. The
speed control lever on the engine and
clutch lever on the marine drive are
connected by remote control cables. There
are various models of remote control
handles available. When using a model
other than shown below, consult the
manufacturer's documentation for more
information.