PERIODIC MAINTENANCE
6LPA Series Operation Manual 67
12/05
Perform the following maintenance every
1000 hours or 4 years of operation,
whichever comes first.
• Checking the Fuel Injection Timing
• Checking the Fuel Injector Pressure
and Nozzle Spray Pattern
•
Replacing the Seawater Pump Impeller
•
Adjusting Intake / Exhaust Valve
Clearance
•
Lapping the Intake and Exhaust Valves
Checking the Fuel Injection Timing
See your authorized Yanmar Marine dealer
or distributor.
Checking the Fuel Injector Pressure
and Nozzle Spray Pattern
See your authorized Yanmar Marine dealer
or distributor.
Checking or Replacing Seawater
Pump Impeller
Figure 17
Figure 17
1 – Impeller
2–O-Ring
3–Cover
4 – Cover Bolts
1. Close the seacock.
2. Drain the seawater cooling system. See
Drain Seawater Cooling System on
page 74.
3. Loosen the cover bolts and remove the
cover and O-ring.
4. Inspect the inside of the seawater
pump with a flashlight. If any of the
following are found, disassembly and
maintenance are required:
• Impeller blades are cracked or nicked.
Edges or surfaces of the blades are
marred or scratched.
• Wear plate is damaged.
5. If no damage is found when inspecting
the inside of the pump, install the O-ring
and cover.
6. If a large amount of water leaks
continuously from the water drain line
below the seawater pump during
operation, replace the mechanical seal.
See your authorized Yanmar Marine
dealer or distributor.
7. When replacement is required, see
your authorized Yanmar Marine dealer
or distributor.
Replace the seawater pump impeller every
1000 hours even if no damage is apparent.
Adjusting Intake / Exhaust
Valve Clearance
See your authorized Yanmar Marine dealer
or distributor.
Lapping the Intake and Exhaust
Valve
See your authorized Yanmar Marine dealer
or distributor.
Every 1000 Hours of Operation